[1]郑志硕,李锋,梁长华,等.低管电压和低流速低剂量对比剂联合高权重深度学习图像重建在冠状动脉计算机体层摄影血管造影中的应用价值[J].新乡医学院学报,2023,40(2):150-153.[doi:10.7683/xxyxyxb.2023.02.010]
 ZHENG Zhishuo,LI Feng,LIANG Changhua,et al.Application value of low tube voltage,low flow rate and low dose contrast agent combined with high-strength deep learning image reconstruction in coronary computed tomography angiography[J].Journal of Xinxiang Medical University,2023,40(2):150-153.[doi:10.7683/xxyxyxb.2023.02.010]
点击复制

低管电压和低流速低剂量对比剂联合高权重深度学习图像重建在冠状动脉计算机体层摄影血管造影中的应用价值
分享到:

《新乡医学院学报》[ISSN:1004-7239/CN:41-1186/R]

卷:
40卷
期数:
2023年2期
页码:
150-153
栏目:
临床研究
出版日期:
2023-02-05

文章信息/Info

Title:
Application value of low tube voltage,low flow rate and low dose contrast agent combined with high-strength deep learning image reconstruction in coronary computed tomography angiography
作者:
郑志硕1李锋1梁长华2梁盼3
(1.新乡市中心医院医学影像科/新乡医学院第四临床学院,河南 新乡 453000;2.新乡医学院第一附属医院放射科,河南 卫辉 453100;3.郑州大学第一附属医院放射科,河南 郑州 450003)
Author(s):
ZHENG Zhishuo1LI Feng1LIANG Changhua2LIANG Pan3
(1.Department of Medical Imaging,Xinxiang Central Hospital/the Fourth Clinical College of Xinxiang Medical University,Xinxiang 453000,Henan Province,China;2.Department of Radiology,the First Affiliated Hospital of Xinxiang Medical University,Weihui 453100,Henan Province,China;3.Department of Radiology,the First Affiliated Hospital of Zhengzhou University,Zhengzhou 450003,Henan Province,China)
关键词:
冠状动脉计算机体层摄影血管造影高权重深度学习图像重建
Keywords:
coronary arterycoronary computed tomography angiographyhigh-strength deep learning image reconstruction
分类号:
R541.4
DOI:
10.7683/xxyxyxb.2023.02.010
文献标志码:
A
摘要:
目的 探讨低管电压和低流速低剂量对比剂联合高权重深度学习图像重建(DLIR-H)在冠状动脉计算机体层摄影血管造影(CCTA)中的应用价值。
方法 选择2022年5~7月新乡市中心医院收治的体质量指数(BMI)为20~27 kg·m-2的60例疑似冠状动脉性心脏病患者为研究对象,按随机数字表法将患者分为观察组和对照组,每组30例。所有患者采用256排宽体探测器CT行CCTA前瞻性心电门控扫描。观察组扫描参数设置:管电压80 kV、自动管电流500~1 300 mA,对比剂注射流速3.5~4.0 mL·s-1,对比剂碘海醇(350 g·L-1)剂量35~40 mL,采用DLIR-H法重建。对照组扫描参数设置:管电压100 kV、自动管电流500~1 040 mA,对比剂注射流速5.0~5.5 mL·s-1,对比剂碘海醇(350 g·L-1)剂量50~55 mL,采用多模型迭代重建50%算法重建。对图像质量进行定量和定性分析,定量指标包括主动脉根部(AO)、左前降支(LAD)、左旋支(LCX)、右冠状动脉(RCA)近段血管的CT值及冠状动脉CT图像信噪比(SNR)和对比噪声比(CNR),定性指标包括图像条纹伪影、血管边缘锐利度及总体图像质量的评分。扫描结束后,统计患者CT剂量指数(CTDI)、放射剂量长度乘积(DLP)及有效辐射剂量(ED)。
结果 观察组患者AO、LAD和RCA的CT值显著高于对照组(P<0.05),2组患者LCX的CT值比较差异无统计学意义(P>0.05)。观察组患者冠状动脉CT图像的SNR显著低于对照组(P<0.05),观察组患者冠状动脉CT图像的CNR显著高于对照组(P<0.05)。观察组患者冠状动脉CT图像条纹伪影、血管边缘锐利度及总体图像质量的评分显著高于对照组(P<0.05);观察组患者ED、DLP、CTDI显著低于对照组(P<0.05)。
结论 对于BMI为20~27 kg·m-2的患者,低管电压和低流速低剂量对比剂联合DLIR-H可生成高质量的CCTA图像。
Abstract:
Objective To investigate the application value of low tube voltage,low flow rate and low dose contrast agent combined with high-strength deep learning image reconstruction (DLIR-H) in coronary computed tomography angiography (CCTA).
Methods A total of 60 patients with suspected coronary heart disease with the body mass index (BMI) of 20-27 kg·m-2 admitted to Xinxiang Central Hospital from May to July 2022 were selected as the research subjects,and the patients were divided into observation group and control group according to the random number table method,with 30 patients in each group.All patients underwent CCTA prospective electrocardiogram gating scan with 256-row wide body detector CT.The parameters in the observation group were set as tube voltage 80 kV,automatic tube current 500-1 300 mA,flow rate of contrast medium 3.5-4.0 mL·s-1,dose of 350 g·L-1contrast medium iohexol 35-40 mL;DLIR-H method was used for reconstruction.The parameters in the control group were set as tube voltage 100 kV,automatic tube current 500-1 040 mA,flow rate of contrast medium 5.0-5.5 mL·s-1,and dose of 350 g·L-1contrast agent iohexol 50-55 mL;the adaptive statistical iterative reconstruction-V 50%algorithm was used for reconstruction.The image quality was analyzed quantitatively and qualitatively.The quantitative indexes included the CT values of aortic root (AO),left anterior descending(LAD),left circumflex(LCX) and proximal vessels of right coronary artery (RCA),as well as the signal to noise ratio (SNR) and contrast to noise ratio (CNR) of coronary artery CT images.The qualitative indexes included the score of image fringe artifacts,vascular edge sharpness and overall image quality.After scanning,the CT dose index(CTDI),radiation dose length product (DLP)and effective dose (ED) of patients were counted.
Results The CT values of AO,LAD and RCA of patients in the observation group were significantly higher than those in the control group (P<0.05).There was no significant difference in the CT value of LCX of patients between the two groups (P>0.05).The SNR of coronary artery CT image of patients in the observation group was significantly lower than that in the control group (P<0.05),and the CNR of coronary artery CT image of patients in the observation group was significantly higher than that in the control group (P<0.05).The scores of fringe artifacts,vascular edge sharpness and overall image quality of coronary artery CT image in the observation group were significantly higher than those in the control group (P<0.05).The ED,DLP and CTDI of patients in the observation group were significantly lower than those in the control group (P<0.05).
Conclusion For the patients with BMI of 20-27 kg·m-2,the low tube voltage,low flow rate and low dose contrast agent combined with DLIR-H can achieve better quality CCTA imaging.

参考文献/References:

[1] RICHARDS C E,OBAID D R.Low-dose radiation advances in coronary computed tomography angiography in the diagnosis of coronary artery disease[J].Curr Cardiol Rev,2019,15(4):304-315.
[2] LIU P J,WANG M,WANG Y N,et al.Impact of deep learning-based optimization algorithm on image quality of low-dose coronary CT angiography with noise reduction:a prospective study[J].Acad Radiol,2020,27(9):1241-1248.
[3] BENZ D C,ERSZL S,MOJON F L A,et al.Radiation dose reduction with deep-learning image reconstruction for coronary computed tomography angiography[J].Eur Radiol,2022,32(4):2620-2628.
[4] 赵正凯,周瀚,程绍玲,等.80 kVp低管电压扫描联合全模型迭代重建冠状动脉CTA成像的临床应用[J].大连医科大学学报,2019,41(6):506-510.ZHAO Z K,ZHOU H,CHENG S L,et al.Clinical application of coronary CTA at 80 kVp combined with iterative model reconstruction[J].J Dalian Med Univ,2019,41(6):506-510.
[5] 国家心血管病专业质控中心心血管影像质控专家工作组,中华医学会放射学分会心胸学组,《中华放射学杂志》心脏冠状动脉多排CT临床应用指南写作专家组.冠状动脉CT血管成像的适用标准及诊断报告书写规范[J].中华放射学杂志,2020,54(11):1044-1055.EXPERT WORKING GROUP OF CARDIOVASCULAR IMAGING OF NATIONAL CENTER FOR MEDICAL QUALITY CONTROL OF CARDIOVASCULAR DISEASES,CHINESE MEDICAL ASSOCIATION RADIOLOGY SOCIETY CARDIAC-CHEST GROUP,CARDIAC AND CORONARY CT ANGIOGRAPHY GUIDELINE WRITING GROUP OF CHINESE JOURNAL OF RADIOLOGY.Standards of appropriate utilization and diagnostic reporting on coronary CT angiography:coronary artery disease-reporting and data system in China[J].Chin J Radiol,2020,54(11):1044-1055.
[6] 赵娜,高扬,徐波,等.基于冠状动脉CT血管成像的狭窄率与斑块特征联合分析对提高CT诊断心肌缺血效能的价值[J].中华放射学杂志,2021,55(1):40-47.ZHAO N,GAO Y,XU B,et al.The value of combined analysis of plaque characteristics and stenosis based on coronary CT angiography in improving CT diagnostic performance for lesion-specific myocardial ischemia[J].Chin J Radiol,2021,55(1):40-47.
[7] RU L,LAN P X,XU C C,et al.The value of coronary CTA in the diagnosis of coronary artery disease[J].Am J Transl Res,2021,13(5):5287-5293.
[8] JUNGMANN F,EMRICH T,MILDENBERGER P,et al.Multidetector computed tomography angiography (MD-CTA) of coronary artery bypass grafts-update 2017[J].Rofo,2018,190(3):237-249.
[9] TUNCAY V,VLIEGENTHART R,DEN DEKKER MAM,et al.Non-invasive assessment of coronary artery geometry using coronary CTA[J].J Cardiovasc Comput Tomogr,2018,12(3):257-260.
[10]马伟,赵娜,高扬,等.应用个体化扫描和碘流率注射方案降低CT心肌灌注成像辐射剂量的可行性研究[J].中华放射学杂志,2021,55(4):409-414.MA W,ZHAO N,GAO Y,et al.Feasibility of individualized scanning and contrast agent injection protocol to reduce the radiation dose of dynamic myocardial perfusion imaging[J].Chin J Radiol,2021,55(4):409-414.
[11] 文雨婷,李万江,李真林,等.超低管电压联合DLIR-H算法在冠状动脉CT血管成像"双低"扫描中的应用价值[J].中国医疗设备,2022,37(2):78-81,88.WEN Y T,LI W J,LI Z L,et al.Application value of ultra low tube voltage combined with DLIR-H algorithm in reducing both radiation and contrast doses in coronary CT angiography[J].Chin Med Devices,2022,37(2):78-81,88.
[12] 孙记航,刘志敏,霍爱华,等.70 kVp联合深度学习算法改进儿童腹部双低CTA图像质量的研究[J].影像诊断与介入放射学,2021,30(1):34-38.SUN J H,LIU Z M,HUO A H,et al.Improving image quality of double-low abdominal CT angiography in children by using 70 kVp and deep learning image reconstruction[J].Diagn Imaging Interv Radiol,2021,30(1):34-38.
[13] TSUKADA J,YAMADA M,YAMADA Y,et al.Comparison of the diagnostic accuracy of FBP,ASiR,and MBIR reconstruction during CT angiography in the evaluation of a vessel phantom with calcified stenosis in a distal superficial femoral artery in a cadaver extremity[J].Medicine,2016,95(27):e4127.
[14] WANG Y R,ZHAN H F,HOU J M,et al.Influence of deep learning image reconstruction and adaptive statistical iterative reconstruction-V on coronary artery calcium quantification[J].Ann Transl Med,2021,9(23):1726.
[15] NODA Y,KAGA T,KAWAI N,et al.Low-dose whole-body CT using deep learning image reconstruction:image quality and lesion detection[J].Br J Radiol,2021,94(1121):20201329.

相似文献/References:

[1]赵国安,李素芬,袁 宇,等.冠状动脉完全闭塞的介入治疗[J].新乡医学院学报,2002,19(04):257.
[2]周俐红-,王 琦,申 彪,等.兔心脏冠状动脉的大体解剖[J].新乡医学院学报,2003,20(02):096.
[3]周俐红,王 琦,申 彪,等.兔心脏冠状动脉的大体解剖[J].新乡医学院学报,2003,20(02):096.
[4]孙志军,武 星,彭 晖,等.RhoA/ROCK信号通路对高糖致大鼠冠状动脉舒缩功能损伤的影响[J].新乡医学院学报,2018,35(12):1043.[doi:10.7683/xxyxyxb.2018.12.001]
 SUN Zhi-jun,WU Xing,PENG Hui,et al.Effect of RhoA/ROCK signal pathway on small coronary arteries impairment of rats induced by high glucose[J].Journal of Xinxiang Medical University,2018,35(2):1043.[doi:10.7683/xxyxyxb.2018.12.001]
[5]金 鹏,李 琳,胡新荣,等.壁冠状动脉心肌桥患者发生冠状动脉粥样硬化的危险因素分析[J].新乡医学院学报,2017,34(8):738.[doi:10.7683/xxyxyxb.2017.08.020]
 JIN Peng,LI Lin,HU Xin-rong,et al.Risk factors for coronary atherosclerosis in patients with coronary artery myocardial bridgemural[J].Journal of Xinxiang Medical University,2017,34(2):738.[doi:10.7683/xxyxyxb.2017.08.020]

更新日期/Last Update: 2023-02-05